两种基于MEMS谐振器的原子力显微镜探针

熊 壮, Mairiaux E , Walter B , Faucher M , Buchaillot L, Legrand B

两种基于MEMS谐振器的原子力显微镜探针

熊壮1, Mairiaux E 2, Walter B 2, Faucher M 2, Buchaillot L2, Legrand B 2

(1.中国工程物理研究院电子工程研究所,四川绵阳621900;2.Institut d’Electronique, de Microélectronique et de Nanotechnologie – IEMN CNRS UMR8520, NAM6 group, France)

摘 要:目前商用原子力显微镜(AFM)大多使用的微悬臂式探针,力灵敏度可达到pN级别。然而受到工艺水平及检测方法限制,微悬臂谐振频率难以超过3.5MHz,且Q值较低,制约了AFM的成像速度以及在液体中的成像效果。另外,光杠杆的检测方法无法与探针本身进行片上集成,较小的悬臂也给激光束的聚焦带来困难。基于以上考虑,本文提出两种基于MEMS谐振器的探针,振频率可达11MHz,Q值为4000,并集成了执行与传感功能以及批量加工纳米针尖的工艺。目前两种探针都已经实现对树脂图案的成像功能,力灵敏度最高可达5pN/√Hz。

关键词:原子力显微镜;MEMS谐振器;静电执行与检测;热执行;压阻检

      中图分类号:TG115.21+5.7       文献标识码:A   

       doi:10.3969/j.1000-6281.2014.02-007

 

wo types of MEMS-based oscillating AFM probes

Zhuang Xiong1*, Estelle Mairiaux2, Benjamin Walter2, Marc Faucher2,

Lionel Buchaillot2, Bernard Legrand2

 (1.Institude of Electronic Engineering, China Academy of Engineering Physics, Mianyang, 629100, China, 2.Institut d’Electronique, de Microélectronique et de Nanotechnologie – IEMN CNRS UMR8520, NAM6 group, France)

Abstract: Most of the commercial Atomic Force Microscope (AFM) oscillating probes are based on micro-scale cantilevers enabling measurement with pico-Newton force resolution in vacuum. However, the cantilever probes suffer from a degradation of both resonance frequency and quality factor when operating in liquids. Moreover, the laser-based vibration sensing unit also limits the integration and miniaturization as the cantilever width has to stay above 2 µm to control the diffraction effect. In such a context, two new concepts of MEMS-based atomic force microscope (AFM) oscillating probes using ring-shaped resonator and I2 shaped resonator are presented. These probes are designed to feature MHz resonance frequencies and high quality factor of several thousands. Thanks to the integrated transduction methods including electrostatic driving/sensing, thermal driving and piezoresistive sensing, the optical detection unit is no longer needed. The probes are fabricated using standard silicon micromachining and the measured resonance frequency can reach up to 11MHz with a quality factor of 1500. Both probes are then mounted onto a commercial AFM set-up through a dedicated probe-holder and circuit board. Topographic images of patterned resist sample are obtained. The minimum force resolution deduced from the measurement is about 5pN/√Hz. The upcoming works consist of improving de detection scheme of the MEMS-based probes and realize high speed/quality AFM images in liquid.

Keywords: Atomic force microscopy (AFM); MEMS resonator; electrostatic actuation and detection; thermal actuation; piezoresistive detection

 